Page Title: Figure 4-7. DC Volts Scale (AN/URM-105) (Sheet 1 of 3).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6640-214-14
Figure 4-7. DC Volts Scale (AN/URM-105) (Sheet 1 of 3).
3. To measure 24 volts dc, plug red lead into "50V" jack on left side of meter. (If measuring less
than 10 volts dc, use "10V" jack. If measuring less than 2.5 volts dc use 2.5V jack.)
(b) Simpson 160.
1. Connect black lead to "COM-" jack.
2. Connect red lead to "+" jack.
3. To measure 24 volts dc, set selector switch to "V/DC 50" position. (If measuring less than 10
volts dc, set selector switch to "V/DC 10" position. If measuring less than 2.5 volts, dc, set selector switch to "V/DC 2.5"
position).
4. Set polarity reversing switch to the "+dc" position.