Click here to make tpub.com your Home Page

Page Title: REMOVAL AND INSTALLATION PROCEDURES. cont'd
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6350-264-14&P-11
NAVELEX EE 181-AA-OMI-120/E121 C-7359-60-1
T.O. 31S9-2FSS9-1-11
Twenty-five-zone power supply is heavy. Use caution when lifting.
o.
To remove twenty-five-zone Monitor Cabinet power supply, unlock and open cabinet door. Unlatch and swing
out the mounting racks just above power supply. Position power supply switch S1 to POWER OFF. Turn off
external ac power by turning off circuit breaker. Remove nuts from captive screws that secure power supply
in cabinet. Slide power supply forward. Tag and disconnect wires from TB3. Remove cable clamps from
power supply cover. Remove screws and lock washers and remove terminal board cover from TB1 on power
supply. Tag and disconnect all interconnecting wires from TB1 and TB2. Lift the power supply at left end and
lower right end off of ledge. Remove power supply from cabinet.
(1)
To remove switch S1 from power supply, remove screws that secure cover and remove cover. Tag,
identify and disconnect wires on switch S1. Remove nut securing switch and remove switch.
(2)
To install new switch, insert new switch and secure with nut. Connect wires to switch. Install cover and
secure with screws.
p.
To install new twenty-five-zone Monitor Cabinet power supply, position power supply in cabinet. Connect all
interconnecting wires to TB1 and TB2. Position terminal board cover on TB1. Install cable clamps on power
supply cover. Connect interconnecting wires to TB3. Install mounting screws. Turn on external ac power by
turning on circuit breaker. Close and latch mounting racks. Close and lock cabinet door.
q.
To remove Status Monitor Module, unlock and open cabinet door. Unlatch and swing out the mounting rack.
Remove mounting screws that hold Status Monitor Module in position. Remove module from mounting rack.
r.
To install new Status Monitor Module, position module in rack and install mounting screws. Close and latch
mounting rack. Close and lock cabinet door.
s.
To remove Status Monitor Module switch S1 or S2, unlock and open cabinet door. Unlatch and swing out
mounting rack. Remove mounting screws that hold Status Monitor Module in position. Remove module from
mounting rack and place on bench. Remove mounting screws and remove side cover. Remove hex nut from
switch. Pull switch to the rear. Tag wires and use a soldering iron of 50 watts maximum to disconnect wires
from switch. Remove switch.
t.
To install new Status Monitor Module switch S1 or S2, use a soldering iron of 50 watts maximum to connect
wires to switch. Position switch in front panel with locating washer next to panel and internal tooth lock
washer next to switch. Install hex nut on switch. Position side cover on module and install mounting screws.
Position Status Monitor Module in mounting rack and install mounting screws. Close and latch mounting rack.
Close and lock cabinet door.
u.
After replacement of major components or assemblies, test the MC for proper operation as follows.
(1)
Turn mode switch on CU to ACCESS, open CU door, and pull Tamper Alarm Switch (TAS) plunger all
the way out. Turn mode switch to TEST/RESET and then to SECURE. Monitor cabinet should indicate
a secure condition.