 |  TM 5-6350-264-14&P-11 NAVELEX EE 181-AA-OMI-120/E121 C-7359-40-1 T.O. 31S9-2FSS9-1-11 Table 5-1. Troubleshooting Procedures - Continued Trouble Probable cause Corrective Action 15. (Cont) b. (Cont) (5) To remove twenty-five-zone power supply, unlock and open cabinet door. Un- latch and swing out two mounting racks just above power supply. Position power supply switch S1 to POWER OFF. Turn off external ac power by turn- ing off circuit breaker. Re- move nuts from captive screws that secure power supply in cabinet. Slide power supply forward. Tag and disconnect wires from TB3. Remove cable clamp from power supply cover. Remove terminal board cover from TB1 on power supply. Tag and dis- connect all interconnecting wires from TB1 and TB2. Lift power supply at left end and lower right end off of ledge. Remove power supply from cabinet. (6) To install new twenty-five- zone Monitor Cabinet pow- er supply, position power supply in cabinet. Connect all interconnecting wires to TB1 and TB2. Position ter- minal board cover on TB1. Install cable clamp on pow- er supply cover. Connect interconnecting wires to TB3. Install mounting screws. Turn on external ac power by turning on cir- cuit breaker. Close and latch mounting racks. Close and lock cabinet door. 5-27 | 