Table 5-1. Troubleshooting Procedures - Continued 
Trouble 
Probable cause 
Corrective Action 
10. (Cont) 
a. 
(Cont) 
screws and lock washers 
and remove terminal board 
cover from TB1 on power 
supply. Tag and discon- 
nect all interconnecting 
wires from TB1, TB2, and 
TB3. Remove nuts from 
captive screws. Slide pow- 
er supply to the right and 
remove from cabinet. 
(2) 
To install new one-zone Mon- 
itor Cabinet power supply, 
position power supply in 
cabinet and install nuts on 
captive screws. Connect all 
interconnecting wires to 
TB1, TB2, and TB3. Posi- 
tion terminal board cover 
on TB1 and install mount- 
ing screws and lock wash- 
ers. Position batteries in 
cabinet and connect ter- 
minal leads. Position 
Status Monitor Module in 
mounting rack (ensure that 
connector is properly en- 
gaged) and install mount- 
ing screws. Position Signal 
Module in mounting rack 
and install mounting 
screws. Connect wires to 
terminal board TB1. Turn 
on external ac power by 
turning on circuit breaker. 
Close and latch mounting 
rack. Close and lock cabi- 
net door. 
(3) 
To remove five-zone Monitor 
Cabinet power supply, un- 
lock and open cabinet 
door. Unlatch and swing 
out mounting rack. Posi- 
tion power supply switch 
S1 to POWER OFF. Turn 
5-17 
 | 
| 
 