Click here to make tpub.com your Home Page

Page Title: Table 7-1. Alarm Module Performance Standards - Continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6350-262-14/9
NAVELEX 0967-466-9090
TO 31S9-4-32-1
Table 7-1. Alarm Module Performance Standards - Continued
Step
Control Setting
Test
Performance
procedure
standard
no.
Test
Equipment
equipment
under test
5.
N/A
(a) Turn Access/
(a) Access lamp on
Secure switch (SW8)
steady secure lamps
on test set to
flashing, audible
N/A
" ecure"
S
alarm.
(b) Touch the scope
(b) Observe asquare
probe to the center
wave of 4-5 p-p
binding pet of
amplitude. 0.21-0.29
either secure
same period.
Depress Ack/Reset
(flashing) lamp.
switch momentarily
(c) None.
(c) Access lamps go
to "Ack".
off, secure lamps on
steady, no audible
alarm.
N/A
(d) Turn Access/
(d) Access lamps
Secure switch (SW3)
flashing, secure lamps
on test set to
on steady, audible
" ccess"
A
.
alarm.
N/A
(e) Turn Access/
(e) Access lamps on
on test set to
flashing, audible
"Secure".
alarm.
N/A
(f) Turn Access
(f) Access lamps
Secure switch (SW3)
flashing, secure lamps
on test set back to
on steady, audible
" ccess"
A
alarm.
Depress Ack/Reset
(g) None.
(g) Secure lamps go
switch momentarily
off., access lamps on
to "Ack'"
steady, no audible
alarm.
6.
None.
N/A
(a) Turn se power
(a) AC power lamps
switch (SW4) on test
flashing, audible
set to "off".
alarm.
Depress Ack/Reset
(b) None
(b) AC power lamps
switch momentarily
off, no audible alarm.
to "Ack"
N/A
(c) Turn ac power
(c) AC power lamp
switch (SW4) on test
flashing, audible
set to "on".
alarm.
Depress Ack/Reset
(d) None.
(d) AC power lamps on
switch momentarily
steady, no audible
to "Ack"
alarm.
CAUTION
Turn power supply off before disconnecting module to
prevent damage to module.
7.
TEST COMPLETE - Turn off and disconnect all test equipment.
7-15