output connector pins J9-14 and -U.  If the duress alarm
signal input is still present after the 10second time period, the
(1) Latched Alarm. When a duress alarm signal is
instantaneous alarm output signal will continue until the alarm
received, an instantaneous latched alarm output signal is
input disappears. Instantaneous no-alarm/alarm signals are
supplied by latched alarmed module A10 if the control unit
applied between terminals 1-I and 1-IR of control unit output
operating mode switch S3 is in either the normal SECURE
terminal board S.  Instantaneous alarms are output in all
position or at ACCESS and switch S5 is in the LATCH
operating modes; secure, test/reset, access, latch, and non-
position. In the secure mode, 20 volts dc is applied to the coil
latch.
of relay A10K2 in the following manner: From S3 pin 2-3
through diode CR2, S5-4, S5-5, and to J10-L. If the operating
mode switch is at ACCESS, regulated 20 volts dc is applied to
(2) Sonalert. Plus 20 volts dc is applied to sonalert
the coil of relay A10K2 from connector pin J1225, through
buzzer DS2 when operating mode switch S3 is in the
diode CR1, switch S5 pins 4 to 5, and to connector pin J10O-
TEST/RESET position.  The buzzer dc return is connected
L. From connector pin J1-8 duress signals are applied to a
through J8-13 to a transistor switch on audible alarm module
silicon controlled rectifier switch through connector pin J10-6
A8.  When the 10-second instantaneous alarm circuit is
for control of relay A1OK1. A no-alarm input signal (0 volts)
activated by a duress alarm signal as described in the
at connector pin J10-6 has no effect on the SCR switch
previous paragraph, 5 volts dc is fed through connector pin
circuit, therefore relay AIOK1 remains in the restored position.
J9-R to J8-14 and applied to the transistor switch. The 5 volts
In this condition a low impedance of 0 to 2000 ohms exists
dc causes the transistor to conduct thereby switching the
between output connector pins J10-9 and -8. This no-alarm
return side of buzzer DS2 to the ground buss. The buzzer will
signal is fed to latched alarm output terminals S1-D and -DR.
sound for 10 2 seconds, until the duress alarm input signal
From J10-9 the signal is routed through the normally closed
is removed, or until operating mode switch S3 is moved from
contacts of relays A9K1, A10K4, A9K2, and A9K3 before
the TEST,/RESET position.
being
c.  Latched Alarm Output.  Latched or non-latched duress
alarm output signals, depending upon the position of switches
S3 and S5, are fed to control unit output terminal board S.
Each of these functions are explained in the following
paragraphs.