TM 38-400/NAVSUP PUB 572/AFMAN 23-210 MCO 4450.14/DLAM 4145.12
13 Column N, Open Unimproved.
2 Column C, General Purpose
Open unimproved storage space refers to an open area
Heated. This is warehouse space in buildings designed
which has not been surfaced but which is actually in use
for storage purposes in which the temperatures can be
(i.e., occupied) for storage purposes.  Vacant open
controlled within specified limits by application of heat.
unimproved is not included.
It does not include space equipped with humidity control
devices or areas specially designed for storage of highly
(c) Line
data
definitions
and
flammable materials or hazardous commodities.
descriptions.
3 Column D, General Purpose
1 Section
A-Gross
Space
Unheated.
General purpose unheated refers to
Available.
All data reported in section A are in
warehouse space, other than controlled humidity and
thousands of SF.
flammable/hazardous, in buildings designed for storage
a
Line 1, Total SF Prior
purposes that are not equipped with heating capability.
Report.  No entry is required since the program will
4 Column E, Controlled Humidity.
automatically enter under columns B through N the total
This is warehouse space equipped with humidity control
SF reported in the prior report.
equipment.
b
Line 2, Total SF This
Period.  Enter under columns C through N all of the
5 Column
F,
Flammable
gross storage space at the installation or activity,
Hazardous. Warehouse space which has been specially
regardless of its location or the purpose for which the
designed for the storage of hazardous and/or flammable
space being used was designed or is designated, which
materials  excluding  explosives,  ammunition,  and
is assigned or used for any operation concerning storage
ammunition components is called flammable/ hazardous
or the support of storage functions at the installation or
space.
activity.
6 Column G, Chill. Chill refers to
c
Line  3,  Unusable  SF.
space in a refrigerated warehouse in which the
Enter under columns C through M the amount of GSF
temperature can be controlled between 32 and 50
F
F
included in the categories defined below:
(O and 10 ).
C
C
(1)
Space
so
7 Freeze.
This is refrigerated
deteriorated that it fails to provide a sufficiently
warehouse space in which the temperature can be
protective environment for the storage of material.
controlled below a level of 32 (O ).
F
C
(2)
Space
that
is
8 Column I, Shed.  All space in
unsafe for storage operations or where its use would be
nonwarehouse buildings without complete side and end
in violation with established regulating criteria.
walls is shed space. It excludes transitory-type shelters.
(3)
Space
that
is
9 Column J, Other.  This is any
restricted from use due to inadequate physical security
space assigned for storage operations within a structure
protection.
designed for other than storage purposes. It includes,
d
Line 4, SF in Standby.
but is not limited to, barracks, dry tanks, hangars,
Enter under column C through M the amount of gross
transitory shelters, and quonset buildings. A transitory
storage space in standby status which is contained in
shelter is a prefabricated sectional, metal structure,
completely empty covered structures, or open improved
normally with complete sides and ends but without
areas which are not required to support the installation's
utilities. A transitory shelter is classified as a storage aid
mission and which have been secured. This entry will
rather than a real property facility.
not include vacant Y-sites (i.e., sites with earthen
10 Column
K,
Magazine.
barricade on four sides). Igloos currently used as fallout
Magazine refers to space in a warehouse (above
shelters will be included and identified under "Remarks."
ground) or igloo (earth covered) type structure used for
Space in completely empty sections of covered
the storage of explosives, ammunition, or loaded
structures that can be isolated and locked is authorized
ammunition components.
to be placed into standby.
e
Line 5, Outgranted SF
11 Column L.  Inert.  Space in a
(non-DOD).  Enter under columns C through N the
warehouse-type structure which is dedicated for the
amount of gross storage space which is outleased,
storage of nonexplosive ammunition or ammunition
licensed, or permitted to private industry or non-DOD
components is classified as inert space.
Government (Federal, state, county, local, or foreign)
12 Column M, Open Improved.
agencies for their operation (e.g., storage space
This is open storage space which has been graded and
identified under support agreement(s) and not
hard surfaced or prepared with topping of some suitable
materials so as to permit effective materials handling
operations.
2-73