Quantcast Figure E-2. Test Cable W2

 

Click here to make tpub.com your Home Page

Page Title: Figure E-2. Test Cable W2
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Figure E1. Test Cable W1
Up
TM-32-6110-003-24-P Distribution Box J-3986/ALQ-151(V) DAAK-20-80-C-0521 Manual
Next
Figure E-3. Connector Assy P8
TM 32-6110-003-24&P
Parts List
1. Connector, 115Vac 3-Phase with Neutral, 400 Hz, Hubbell Twist-Lock or equivalent
2. Wire 18 AWG/3 TAISHO-HANCHANG, LL34320 CSA POT-32 or equivalent, length as required
3. Connector, MS3106R24-10S
Wire List
From
To
115 Vac Q1
C
Connector
P1
115 Vac Q2
D
Connector
P1
115 Vac Q3
E
Connector
P1
Neutral
F
Connector
P1
Ground
G
Connector
P1
Figure E-2. Test Cable W2