Repair Procedures.
Up
TM-32-6110-003-24-P Distribution Box J-3986/ALQ-151(V) DAAK-20-80-C-0521 Manual
Next
Relay K4 Removal and Replacement
TM 32-6110-003-24&P
Figure 5-6. Circuit Breaker Replacement
(2) If needed, remove the high-voltage shield (5) in accordance with paragraph 5-10b, and the RFI filter
assembly (6) in accordance with paragraph 5-10c.
(3) Remove the collar nut (19) and lock washer (20) that secure the circuit breaker (18) to the front
panel (16). Remove the circuit breaker.
(4) Tag the wires to identify circuit breaker (18) connections.
(5) Remove the wires from the circuit breaker (18).
(6) Attach the wires to the replacement circuit breaker (18) as tagged.
(7) Remove the collar nut (19) and lock washer (20) from the replacement circuit breaker. Aline the
circuit breaker in the front panel (16).
5-23