Click here to make tpub.com your Home Page

Page Title: Table 7-5. Troubleshooting Monitor Control Panel SB-2600/G - Continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 32-5895-227-14&P
Table 7-5. Troubleshooting Monitor Control Panel SB-2600/G - Continued
Item
Trouble symptom
Probable trouble
Corrective action
number
5
Inability to record
Defective switch S3, S5, or S6
Refer to FO-8. Check continuity of
receiver output on
switch function. Isolate contact failure,
recorder No. 1
remove and replace switch.
Defective relay K1, K2, or K3
Refer to FO-8. Check continuity of relay
function. Isolate contact failure; remove
and replace relay.
Defective resistor R1
Refer to FO-8. Check 10 k ohm
resistance. If no resistance, remove and
replace R1.
6
Inability to record
Defective switch S4, S7, or S8
Refer to FO-8. Check continuity of
receiver output on
switch functions. Isolate control failure,
recorder No. 2
remove and replace switch.
Defective relay K4, K5, or K6
Refer to FO-8. Check continuity of relay
function. Isolate contact failure; remove
and replace relay.
Defective resistor R2
Refer to FO-8. Check 10 k ohm
resistance
If no resistance, remove and replace R2.
7
Inoperable REC
Defective switch S9
Refer to FO-8. Check continuity of
MON switch.
switch function. Isolate contact failure,
remove and replace switch.
Defective relay K3 or K6
Refer to FO-8. Check continuity of relay
function. Isolate contact failure; remove
and replace relay.
8
Inoperable MIKE
Defective switch S10
Refer to FO-8. Check continuity of
DUB switch.
switch function. Isolate contact failure,
remove and replace switch.
Defective relay K3 or K6
Refer to FO-8. Check continuity of relay
function. Isolate contact failure; remove
and replace relay.
Defective amplifier No. 4
Refer to FO-8. Interchange amplifier
No. 4 with amplifier No. 1, No. 2, No. 3,
or No. 5. Replace defective components
on amplifier No. 4.
Defective mike
Interchange mike from another position.
Replace defective mike.
9
ICOM blinkers fail to
Defective switch S7
Refer to FO-8. Check continuity of
operate.
switch function. Isolate contact failure,
remove and replace switch.
7-19